XTUN-1009
5
XTUN-1009
Message
FCIP OSTP <Number of FCP write commands that were purged> Write blocks purged due
to PLOGI slot=<FX8-24 Slot number (0 for 7800 or 7840)> DP=<FX8-24/7840 DP number
(or 0 if 7800)> SFID=<SFID of the initiator> DFID=<DFID of the tape device>
SID/DID/Lun=0x<SID of the initiator>/<DID of the tape device>/<The tape device LUN
number>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that more than one outstanding write command that were purged due to the receipt of a new
PLOGI sequence. This can indicate missing blocks on the currently mounted tape. If the tape job
resumed after this error, you must confirm the integrity of the data on the tape.
Recommended
Action
Contact your vendor's customer support for assistance.
XTUN-1996
Message
FTRACE buffer <FTRACE Trace Buffer Number> on slot <FX8-24 Slot Number (0 for 7800
and 7840)> DP <FX8-24/7840 DP Number (or 0 if 7800)> has been cleared.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a CLI command or supportSave operation freed the trace buffer back into the FTRACE
free pool.
Recommended
Action
No action is required.
XTUN-1997
Message
FTRACE buffer <FTRACE Trace Buffer Number> on slot <FX8-24 Slot number (0 for 7800
or 7840)> dp <FX8-24/7840 DP number (or 0 if 7800)> has been triggered.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a programmed trigger event has been detected.
Recommended
Action
If there was an unexpected job failure associated with this event, contact your vendor's customer support
for assistance.