Ss-1009, Ss-1010, Ss-1011 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 894

872
Fabric OS Message Reference
53-1003140-01
SS-1009
5
SS-1009
Message
<slot number and its node name(BP/DP)> supportsave failed. Reason:No ISC
connection for <slot number and its node name(BP/DP)>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there is no Inter-Subsystem Communication (ISC) connection for the specified node slot.
Recommended
Action
Restart the switch using the reboot command and then execute the supportSave command.
SS-1010
Message
CORE/FFDC files have been uploaded to the host with IP address <host ip>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the supportSave command was used to transfer core and first failure data capture (FFDC)
files to a remote location.
Recommended
Action
No action is required.
SS-1011
Message
CORE/FFDC files have been transferred to the USB storage device.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the supportSave command was used to transfer core and first failure data capture (FFDC)
files to a USB storage Device.
Recommended
Action
No action is required.