Chs messages, Chs-1002, Chs-1003 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 257: Chs-1004

Fabric OS Message Reference
235
53-1003140-01
CHS-1002
5
CHS Messages
CHS-1002
Message
ki_gd_register_action failed with rc = <return val>.
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates an internal error.
Recommended
Action
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.
CHS-1003
Message
Slot ENABLED but Not Ready during recovery, disabling slot = <slot number> rval =
<return value>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
Action
For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.
For a non-bladed switch, restart or power cycle the switch.
CHS-1004
Message
Blade attach failed during recovery, disabling slot = <slot number>, rval =
<return value>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified blade has failed during failover or recovery.
Recommended
Action
For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.