Em-1037, Em-1042, Em-1043 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 330

308
Fabric OS Message Reference
53-1003140-01
EM-1037
5
EM-1037
Message
<FRU Id> is no longer faulted.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified power supply is no longer marked faulty; probably because its AC power
supply has been turned on.
Recommended
Action
No action is required.
EM-1042
Message
Important FRU header data for <FRU Id> is not valid.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU
header-derived information. This could mean that the FRU header was corrupted or read incorrectly, or
corrupted in the object database, which contains information about all FRUs.
Recommended
Action
Reseat the FRU. If the problem persists, replace the FRU.
EM-1043
Message
Can't power <FRU Id> <state (on or off)>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified field-replaceable unit (FRU) cannot be powered on or off.
Recommended
Action
The specified FRU is not responding to the commands and should be replaced.