Ras-3001, Ras-3002, Ras-3003 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 754: Ras-3004

732
Fabric OS Message Reference
53-1003140-01
RAS-3001
5
RAS-3001
Message
USB storage device plug-in detected.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the USB storage device plug-in has been detected.
Recommended
Action
No action is required.
RAS-3002
Message
USB storage device enabled.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the USB storage device has been enabled.
Recommended
Action
No action is required.
RAS-3003
Message
USB storage device was unplugged before it was disabled.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the USB storage device was unplugged before it was disabled.
Recommended
Action
No action is required. It is recommended to disable the USB storage device using the usbstorage -d
command before unplugged it from the system.
RAS-3004
Message
USB storage device disabled.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the USB storage device has been disabled.