Fabr-1051, Fabr-1052, Fabr-1053 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 376

354
Fabric OS Message Reference
53-1003140-01
FABR-1051
5
FABR-1051
Message
D-Port <Testname> test failed for slot <Slot> and port <Port>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the D_Port test failed for the given slot and port due to one of the following reasons:
•
The small form-factor pluggable (SFP) fault detected by electrical loopback test failure.
•
The cable fault detected by optical loopback test failure.
•
An application-specific integrated circuit (ASIC) issue detected by link traffic test failure.
Recommended
Action
Replace the faulty SFPs, cables, or blade.
FABR-1052
Message
The configured port speed is invalid. Persistently disabling port <Port that is
being disabled>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the configured speed for the specified port is invalid.
Recommended
Action
Execute the portCfgSpeed command to change the port speed.
FABR-1053
Message
The switch is disabled due to an inconsistency found in the interop config
parameters.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the configuration keys have interopmode parameters such as switch.interopMode and
switch.mcdtFabricmode set.
Recommended
Action
Execute the interopmode command to reset the parameters.