Cvlm-1004, Cvlm-1005, Cvlm-1006 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 302: Cvlm-1007

280
Fabric OS Message Reference
53-1003140-01
CVLM-1004
5
CVLM-1004
Message
Crypto device configuration between local switch (<local switch WWN>) and peer
(<peer switch WWN>) is out of sync. New encryption session is not allowed.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that encryption engine nodes in the cluster encryption group have different configurations.
Recommended
Action
Synchronize the configuration in the cluster group using the cryptocfg --commit command.
CVLM-1005
Message
Crypto service is <status> on the switch.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the crypto service is enabled or disabled on the switch.
Recommended
Action
No action is required.
CVLM-1006
Message
Crypto device <device WWN> in target container <container name> is not in AD0.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the crypto device in the crypto target container is not in root zone database (AD0).
Recommended
Action
Use the ad command to move the crypto device into AD0.
CVLM-1007
Message
Redirect zone update failure. Status is <status>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the redirect zone update has failed.