Anv-1016, Anv-1028 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 176

154
Fabric OS Message Reference
53-1003140-01
ANV-1016
5
ANV-1016
Message
Port is faulted due to port reinitialization failure on internal port S<slot
number>,P<port number>(<blade port number>) with reason <port fault reason>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified port is faulted due to port re-initialization failure.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.
ANV-1028
Message
Detected excessive Link resets on the port in a second. Slot <slot number>, Port
<port number>(<blade port number>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the port received excessive link resets from peer port within 1 second and that exceeded
threshold.
Recommended
Action
When this error is observed persistently, change the small form-factor pluggable (SFP) transceiver or the
cable on the peer port to which this port is connected.