Trce-1010, Trce-1011, Trce-1012 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 949

Fabric OS Message Reference
927
53-1003140-01
TRCE-1010
5
TRCE-1010
Message
Traced fails to start.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the trace daemon (traced), which is used for transferring the trace files has failed to start.
The trace capability within the switch is unaffected. The system automatically restarts the traced facility
after a brief delay.
Recommended
Action
Reboot the CP (dual-CP system) or restart the switch.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
TRCE-1011
Message
Trace dump manually transferred to target ' <optional string to indicate which
slot the trace dump is transferred> ': <result>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the trace dump files were transferred manually to the specified slot.
Recommended
Action
No action is required.
TRCE-1012
Message
The system was unable to retrieve trace information from slot <Slot number of the
interface module on which the attempt was made>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the system was unable to retrieve trace information from the specified slot because there is
no communication between the main system and the slot.
Recommended
Action
Check that the interface module is enabled and retry the command. If the interface module is already
enabled, execute the supportSave command and contact your switch service provider.