Ficn-1063, Ficn-1064, Ficn-1065 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 453

Fabric OS Message Reference
431
53-1003140-01
FICN-1063
5
FICN-1063
Message
Egress Abort:Oxid=0x<the OXID of the aborted exchange>:Path=0x<VEPortNumber
HostDomain HostPort DeviceDomain><DevicePort LPAR CUADDR
DeviceAddr>:LastStates=0x<prior emulation state array><previous emulation
state><current emulation state>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an abort operation has been received from a peer FC interface for an active emulation
exchange.
Recommended
Action
This is an unexpected event; contact your vendor's customer support for assistance.
FICN-1064
Message
Ingress Abort:Oxid=0x<the OXID of the aborted exchange>:Unknown Path on
GEPort=<GEPortNumber> VEPort=<VEPortNumber> from SID=0x<Source Domain><Source
Port> to DID=0x<Destination Domain><Destination Port>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates an abort operation has been received from a local FC interface for an exchange.
Recommended
Action
If there were associated I/O errors at the same time as this event, contact your vendor's customer
support for assistance.
FICN-1065
Message
Egress Abort:Oxid=0x<the OXID of the aborted exchange>:Unknown Path on
GEPort=<GEPortNumber> VEPort=<VEPortNumber> from SID=0x<Source Domain ><Source
Port> to DID=0x<Destination Domain><Destination Port>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates an abort operation has been received from a peer FC interface for an exchange.
Recommended
Action
If there were associated I/O errors at the same time as this event, contact your vendor's customer
support for assistance.