Ms-1005, Ms-1006, Ms-1008 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 697

Advertising
background image

Fabric OS Message Reference

675

53-1003140-01

MS-1005

5

MS-1005

Message

MS Invalid CT Response from d=<domain>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Management Server (MS) received an invalid common transport (CT) response from
the switch domain. MS expects either a CT accept IU or a reject IU; the MS received neither response,
which violates the Fibre Channel - Generic Services (FS-GS) specification.

Recommended

Action

Check the integrity of the FC switch at the specified domain. It is not sending correct MS information as
defined by the Fibre Channel - Framing and Signaling (FC-FS) standard.

MS-1006

Message

MS Unexpected iu_data_sz=<number of bytes>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Management Server (MS) received an information unit (IU) data of unexpected size.
The IU payload and the IU size may be inconsistent with each other or with the command that is currently
being processed.

Recommended

Action

Wait a few minutes and try the operation again.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

MS-1008

Message

MS Failure while initializing <action>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Management Server (MS) failed while initializing the specified action. This message is
often transitory.

The action can be one of the following:

while writing to ms_els_q: MS is unable to write a message to the MS Extended Link Service
Queue.

while inserting timer to timer list: MS is unable to add a timer to a resource.

Recommended

Action

If the error persists, check the available memory on the switch using the memShow command.

Advertising