C3-1015, C3-1016, C3-1017 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 239

Fabric OS Message Reference
217
53-1003140-01
C3-1015
5
C3-1015
Message
Port re-initialized due to Link Reset failure on internal Port S<slot
number>,P<port number>(<blade port number>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified port is re-initialized due to link reset failure.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.
C3-1016
Message
Port is faulted due to port re-initialization failure on internal Port S<slot
number>,P<port number>(<blade port number>) with reason <port fault reason>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified port failed due to port re-initialization failure.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.
C3-1017
Message
Blade in Slot-<slot number> failed due to unavailability of ports in the internal
trunk.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified blade failed because of the unavailability of the ports in the internal trunk.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.