Safety engineering

Error management
Error states

1

l

104

EDS94AYAE EN 7.0

1.7

Error management

1.7.1

Error states

Detected errors or maloperation of the drive are assigned to error statuses with definite
reactions. The reaction can be co−ordinated with the complete drive via the error statuses.

Features

Error status

System error

Trouble

Warning

Event

Fatal internal error

Fault

Monitoring function

LED "ME"

On

Blinking

Flashing

Status of safety module

Lockout (CPU stopped)

Error status

Normal operation

The control category
according to
EN ISO 13849−1 ...

... has been abandoned

... has been abandoned

... has not been abandoned

Response

The motor immediately
switches to torque−free
operation via

l

STO

The motor is stopped via

l

STO or

l

SS1

Acknowledgement after
deactivated event

l

Connection and
disconnection of the
24−V supply at the
safety module

l

Fault acknowledgement (AIE) via terminal X82.2
(positive signal pulse with a signal time of
0.3 ... 10 s)

l

Fault acknowledgement (AIE) via the safety bus
(Bit "PS_AIE")

l

Connection and disconnection of the 24−V supply at
the safety module

Tab. 1−19

Overview of error statuses

More error messages are listed in the appendix.

)

Note!

If the system fault also occurs after switching the 24−V supply, please contact
the service.

When using PROFIsafe as safety bus:

ƒ

If faults occur in the PROFIsafe communication, the data is passivated by the
PROFIsafe driver.

ƒ

After the PROFIsafe communication is reinitialised, the drive is automatically
enabled again if no standstill function is selected.

ƒ

Events which cause an error status are sent as diagnostic telegram via the safety
bus.