Safety engineering, Safety functions general information, Codes – Lenze E94AYAE SM301 User Manual

Page 49

Advertising
background image

Safety engineering

Safety functions

General information

1

l

49

EDS94AYAE EN 7.0

Codes

Parameter:

Name:

Data type:

Index:

C15305

SS1, SS2: Stopping time

UNSIGNED_16

9270

d

= 2436

h

Stopping time for the SS1 and SS2 safety functions

Setting range

(min. value | unit | max. value)

Information

0

MS

30000 Lenze: 0, increment: 2 ms

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15306

SS1 mode

UNSIGNED_8

9269

d

= 2435

h

Selection list

(Lenze setting bold)

Information

0 STO after stopping time

(From SM301 V1.3)

1 STO at n = 0

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

Advertising