Safety engineering

Appendix

Module error messages

1

l

135

EDS94AYAE EN 7.0

Error type/response/
Note

Description

Field

Error type/response/
Note

Description

Error number

Safety functions

97

0x61

SS1/SS2: Stopping time exceeded
(The drive has not reached zero speed within the stopping time.)

Warning/STO

98

0x62

SLS1: Nlim1 exceeded
(The drive has exceeded the limited speed.)

Warning/response can be
set

99

0x63

SLS2: Nlim2 exceeded
(The drive has exceeded the limited speed.)

Warning/response can be
set

100

0x64

SLS3: Nlim3 exceeded
(The drive has exceeded the limited speed.)

Warning/response can be
set

101

0x65

SLS4: Nlim4 exceeded
(The drive has exceeded the limited speed.)

Warning/response can be
set

102

0x66

SLS/SMS: Error stop not executed
(The drive has exceeded the limited speed or maximum speed and
has not stopped the drive safely. Following error to no. 0x62 or
0x69)

Warning/STO

103

0x67

SDIpos: Wrong direction of movement

Warning/response can be
set

104

0x68

SDIneg: Wrong direction of movement

105

0x69

SMS: Nmax exceeded
(The drive has exceeded the monitored maximum speed.)

Warning/response can be
set

106

0x6A

SOS: Tolerance limit exceeded
(The drive has exceeded a tolerance limit.)

Warning/STO

107

0x6B

No encoder system parameterised
(SMS, SLS1 or SS2 are tried to be executed without an encoder
being parameterised.)

Warning/STO

108

0x6C

CAS: Circulation time exceeded
Maximum time between release and feedback of the cascading
function has been exceeded.

Warning/STO

109 0x6D

CAS: Hardware or discrepancy error
The cascading output has not been switched off quickly enough
by the hardware or there is a discrepancy at the cascading input.

Warning/STO

110

0x6E

SS1/SS2: Speed ramp exceeded
Monitoring of the speed ramp is activated. When the stop
function SS1/SS2 is executed, the deceleration of the speed ramp
is monitored. When the monitoring limits are exceeded, an error is
reported.

Warning/STO

111

0x6F

SLI: Safely limited increment exceeded
The safely limited increment is monitored in the special operation
mode. The parameterised increment has been exceeded.

Warning/STO

Test functions − output

128

0x80

Stuck at High SD−Out1, channel A
(Short circuit (High))

Trouble/−
SD−Out1: OFF state

129

0x81

Stuck at Low SD−Out1, channel A
(Short circuit (Low))

130

0x82

Stuck at High SD−Out1, channel B

131

0x83

Stuck at Low SD−Out1, channel B