Safety engineering, Safety functions safe stop 2, Codes – Lenze E94AYAE SM301 User Manual
Page 63: 2 activation how to activate the function, As response to the error stop request

Safety engineering
Safety functions
Safe stop 2
l
63
EDS94AYAE EN 7.0
Codes
Parameter:
Name:
Data type:
Index:
C15300
Restart behaviour
UNSIGNED_8
9275
d
= 243B
h
Behaviour for restart after functions have been cancelled
Selection list
(Lenze setting bold)
Information
0 Acknowledged restart
1 Automatic restart
Subcodes
Information
C15300/1
Restart - STO, SS1
C15300/2
Restart - SS2, SOS
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer
C15305
SS1, SS2: Stopping time
UNSIGNED_16
9270
d
= 2436
h
Stopping time for the SS1 and SS2 safety functions
Setting range
(min. value | unit | max. value)
Information
0
MS
30000 Lenze: 0, increment: 2 ms
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer
C15308
SS2 mode
UNSIGNED_8
9267
d
= 2433
h
Selection whether SS2 is to be executed already after reaching n=0 SOS or only after reaching the parameterised
stopping time.
Selection list
(Lenze setting bold)
Information
0 SOS after stopping time
(As of SM301 V1.3)
1 SOS at n = 0
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer
C15310
Tolerance window (n=0)
INTEGER_16
9265
d
= 2431
h
Safely monitored tolerance window for zero speed
Setting range
(min. value | unit | max. value)
Information
0
rpm
16000 Lenze: 0
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer
C15311
SOS: Tolerance window (Delta p=0)
UNSIGNED_32
9264
d
= 2430
h
Safely monitored tolerance window for zero position change
Display area
(min. value | unit | max. value)
Information
0
Incr.
327680 Lenze: 0
(From SM301 V1.3)
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer
C15312
SOS: Maximum change in position
UNSIGNED_32
9263
d
= 242F
h
Amount of the maximum change in position while SOS was active
Display area
(min. value | unit | max. value)
Information
0
Incr.
2147483647
(From SM301 V1.3)
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
1.3.5.2
Activation
How to activate the function:
ƒ
"OFF state" at a safe input, the function of which has been assigned by parameter
setting.
ƒ
Via a safety bus data telegram with corresponding content.
ƒ