Function mode of the safety modules, Safety engineering – Lenze E94AYAE SM301 User Manual

Page 14

Advertising
background image

Safety engineering

Device modules
Function mode of the safety modules

1

l

14

EDS94AYAE EN 7.0

1.2.2

Function mode of the safety modules

C00214

The setting in C00214 must comply with the plug−in safety module type so that the
controller is able to operate.

Disconnecting paths

The transmission of the pulse width modulation is safely disconnected by the safety
module. Hence the drivers do not create a rotating field. The motor is safely switched to
torqueless operation (STO).

M

SMx

PWM

µC

P

C

3x

3x

Xx

SSP94SM320

Fig. 1−1

Disconnecting paths of the safety modules

SMx

Safety module

xx

Input / output terminal

C

Control section

mC

Microcontroller

PWM

Pulse width modulation

P

Power section

M

Motor

Safety status

When the controller is switched off by the safety module, the controller switches to the
"Safe torque off"device state.

ƒ

"Controller in STO state" is entered into the logbook (0x00750003).

ƒ

"Safe torque off active" is displayed in C00183.

Fail−safe status

)

Note!

If internal errors of the safety modules are detected, the motor is safely
switched to torque−free operation (fail−safe status).

Advertising