Safety engineering, Appendix module internal codes – Lenze E94AYAE SM301 User Manual

Page 113

Advertising
background image

Safety engineering

Appendix

Module internal codes

1

l

113

EDS94AYAE EN 7.0

Parameter:

Name:

Data type:

Index:

C15000

Status of safety functions

BITFIELD_32

9575

d

= 2567h

Bit coded status word of the safety functions

Value is bit coded:

Information

Bit 0 STO active

Safe torque off

Bit 1 SS1 active

Safe stop 1

Bit 2 SS2 active

Safe stop 2

Bit 3 SLS1 active

Safely limited speed 1

Bit 4 SLS2 active

Safely limited speed 2

(From SM301 V1.1)

Bit 5 SLS3 active

Safely limited speed 3

(From SM301 V1.1)

Bit 6 SLS4 active

Safely limited speed 4

(From SM301 V1.1)

Bit 7 SDIpos is active

Safe direction, positive

(From SM301 V1.3)

Bit 8 SDIneg is active

Safe direction, negative

(From SM301 V1.3)

Bit 9 ES active

Safe enable switch

Bit 10 SLI is active

Safely limited increment

(From SM301 V1.4)

Bit 11 OMS

Safe operation mode selector

Bit 12 Reserved

...

Bit 15 Reserved

Bit 16 SOS monitored

Safe operational stop is monitored.

Bit 17 SLS1 monitored

Safely limited speed 1 is monitored.

Bit 18 SLS2 monitored

Safely limited speed 2 is monitored.

(From SM301 V1.1)

Bit 19 SLS3 monitored

Safely limited speed 3 is monitored.

(From SM301 V1.1)

Bit 20 SLS4 monitored

Safely limited speed 4 is monitored.

(as of SM301 V1.1)

Bit 21 SDIpos is monitored

Safe positive direction is monitored.

(From SM301 V1.3)

Bit 22 SDIneg is monitored

Safe negative direction is monitored.

(From SM301 V1.3)

Bit 23 SSE active

Emergency stop function

Bit 24 SD−In1 active

Safe input

Bit 25 SD−In2 active

Safe input

Bit 26 SD-In3 active

Safe input

Bit 27 SD−In4 active

Safe input

Bit 28 Reserved

Bit 29 OMS active

Special operation is active

(as of SM301 V1.1)

Bit 30 Reserved

Bit 31 Error active

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer