Safety engineering, Appendix module internal codes – Lenze E94AYAE SM301 User Manual

Page 114

Advertising
background image

Safety engineering

Appendix
Module internal codes

1

l

114

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15003

Command status

UNSIGNED_16

9572

d

= 2564

h

Status of the current command.

l

In high byte the command is repeated.

l

In low byte the status is displayed:
0x00:

no command

0x01:

command executed

0x02:

password invalid

0x03:

command in process

0x04:

command unknown

0x05:

command error

Display area

(min. value | unit | max. value)

Information

0

2309

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15010

Parameter set status

UNSIGNED_8

9565

d

= 255D

h

Status of the parameter set

Selection list

(read only)

Information

0 No parameter set

1 Parameter set valid

2 Read error − memory module

3 Parameter set dissimilar

4 CRC error

5 Version error

6 Format error

7 Plausibility error

8 Assignment error

9 Local read error

10 Communication error GG

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15011

Parameter CRC

UNSIGNED_32

9564

d

= 255C

h

Parameter checksum (CRC = Cyclic Redundancy Code)

Display area

(min. value | unit | max. value)

Information

0

4294967295

Subcodes

Information

C15011/1

CRC safety module

C15011/2

CRC memory module

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15013

Time for parameter set creation

UNSIGNED_64

9562

d

= 255A

h

Time of parameter set creation

Display area

(min. value | unit | max. value)

Information

0

1844674407370

96E+19

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15014

Time − RTC parameter setting

VISIBLE_STRING

9561

d

= 2559

h

Time of parameter set transfer from the memory module as a value of the real−time clock (RTC).

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15015

Time sec. parameter setting

UNSIGNED_32

9560

d

= 2558

h

Time of parameter set transfer from the memory module as a value of the power−on time meter from the
controller.

Display area

(min. value | unit | max. value)

Information

0

S

4294967295

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer