Safety engineering, Appendix module internal codes – Lenze E94AYAE SM301 User Manual

Page 132

Advertising
background image

Safety engineering

Appendix
Module internal codes

1

l

132

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

8682

d

= 21EA

h

BITFIELD_64

Log state

C15893

Bit 48 FailSafeValues via control word

Safe replacement values on the safety bus were
activated via the control word.

Bit 49 FailSafeValues through error

Safe replacement values on the safety bus were
activated through an error.

Bit 50 Reserved

Bit 51 Reserved

Bit 52 SD−In1 active

The safe input SD−In1 has been switched on.

Bit 53 SD−In2 active

The safe input SD−In2 has been switched on.

Bit 54 SD-In3 active

The safe input SD−In3 has been switched on.

Bit 55 SD−In4 active

The safe input SD−In4 has been switched on.

Bit 56 Reserved

...

Bit 63 Reserved

Subcodes

Information

C15893/1

Log state n

C15893/2

Log state n−1

...

C15893/10

Log state n−9

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15900

Firmware − product type

VISIBLE_STRING

8675

d

= 21E3

h

Display of the product type (E94AFAE)

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15901

Firmware − compilation date

VISIBLE_STRING

8674

d

= 21E2

h

Display of the compilation date

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15902

Firmware version

VISIBLE_STRING

8673

d

= 21E1

h

Software version of the firmware, e.g.: "V1.0"

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

Advertising