Safety engineering

Safety functions
Safe stop 1

1

l

58

EDS94AYAE EN 7.0

Codes

Parameter:

Name:

Data type:

Index:

C15300

Restart behaviour

UNSIGNED_8

9275

d

= 243B

h

Behaviour for restart after functions have been cancelled

Selection list

(Lenze setting bold)

Information

0 Acknowledged restart

1 Automatic restart

Subcodes

Information

C15300/1

Restart - STO, SS1

C15300/2

Restart - SS2, SOS

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15305

SS1, SS2: Stopping time

UNSIGNED_16

9270

d

= 2436

h

Stopping time for the SS1 and SS2 safety functions

Setting range

(min. value | unit | max. value)

Information

0

MS

30000 Lenze: 0, increment: 2 ms

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15306

SS1 mode

UNSIGNED_8

9269

d

= 2435

h

Selection list

(Lenze setting bold)

Information

0 STO after stopping time

(From SM301 V1.3)

1 STO at n = 0

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15307

SS1: Deceleration STO after n=0

UNSIGNED_16

9268

d

= 2434

h

Display area

(min. value | unit | max. value)

Information

0

ms

30000 Lenze: 0, increment: 2 ms

(From SM301 V1.3)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15310

Tolerance window (n=0)

INTEGER_16

9265

d

= 2431

h

Safely monitored tolerance window for zero speed

Setting range

(min. value | unit | max. value)

Information

0

rpm

16000 Lenze: 0

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer