Response times of the inputs, Response time of the safe output, Response times of the safety bus – Lenze E94AYAE SM301 User Manual

Page 108: Safety engineering, Response times response times of the inputs, 1 response times of the inputs, 2 response time of the safe output, 3 response times of the safety bus profisafe

Advertising
background image

Safety engineering

Response times
Response times of the inputs

1

l

108

EDS94AYAE EN 7.0

1.8.1

Response times of the inputs

Response time to an event in the sensors

Time interval (Fig. 1−14)

[ms]

t

1

Response time of the sensors

according to manufacturer

information

t

2

Input delay of the safe inputs

C15034:

0 ... 100

Input error:

2

t

i

Processing time in drive−based safety

4

Safety function starts after ...

S

Tab. 1−20

Response time to an event in the sensors

1.8.2

Response time of the safe output

Response time of the safe output to a safety function

[ms]

Safe output SD−Out1 switches to ...

4

Tab. 1−21

Response time − safe output

1.8.3

Response times of the safety bus

PROFIsafe

Response time to an event in the safety sensors (PROFIsafe input data)

Time interval (Fig. 1−14)

[ms]

t

1

Response time of the sensors

according to manufacturer

information

t

2

Input delay of the safe inputs

C15034:

0 ... 100

Input error:

2

t

3

Processing time in drive−based safety

24

PROFIsafe input data ready for transmission to ...

S

t

Ps

PROFIsafe cycle time

according to manufacturer

information

PROFIsafe input data ready for processing in the safety PLC ...

S

Tab. 1−22

Response time to an event in the sensors

Advertising