Safety engineering

Appendix
Module internal codes

1

l

130

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15821

Service code

INTEGER_16

8754

d

= 2232

h

for Lenze service: Currently monitored speed value of ramp monitoring.

Display area

(min. value | unit | max. value)

Information

−16000

rpm

16000

Displayed value is only valid if SS1 or SS2 are active
with ramp monitoring.

(From SM301 V1.4)

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15822

Service code

INTEGER_16

8753

d

= 2231

h

for Lenze service: Minimum differences between actual speed value and monitored ramp.

Display area

(min. value | unit | max. value)

Information

−16000

rpm

16000 The value is kept until the ramp monitoring is

restarted.

(From SM301 V1.4)

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15890

Current time

UNSIGNED_32

8685

d

= 21ED

h

Relative time for use in logbook.

Display area

(min. value | unit | max. value)

Information

0

ms

4294967295

(From SM301 V1.4)

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15891

Log function

UNSIGNED_8

8684

d

= 21EC

h

Setting of the logging behaviour (trigger condition).

(From SM301 V1.4)

Selection list

Information

0 Logging is active

Logging is always active.

1 Logging is stopped

Logging is switched off.

2 Stop logging in case of error

Logging is stopped if an error occurs.

3 Stop logging in case of STO

Logging is stopped if STO occurs.

4 Stop logging in case of SS1

Logging is stopped if SS1 occurs.

5 Stop logging in case of SS2

Logging is stopped if SS2 occurs.

þ Read access þ Write access o Controller inhibit o PLC-STOP o No transfer

C15892

Log time

UNSIGNED_32

8683

d

= 21EB

h

Time of log entry.

Display area

(min. value | unit | max. value)

Information

0

ms

4294967295

(From SM301 V1.4)

Subcodes

Information

C15892/1

Log time n

C15892/2

Log time n−1

...

C15892/10

Log time n−9

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15893

Log state

BITFIELD_64

8682

d

= 21EA

h

Logged state

Display area

Information

(From SM301 V1.4)

Value is bit−coded

Information

Bit 0 STO via SD−In

STO was triggered via a safe input.

Bit 1 STO via S−bus

STO was triggered via the safety bus.

Bit 2 STO through error

STO was triggered through an error.

Bit 3 Reserved