Safety engineering

Safety functions
Safe direction

1

l

76

EDS94AYAE EN 7.0

Codes

Parameter:

Name:

Data type:

Index:

C15340

SDI: Monitoring − normal operation

UNSIGNED_8

9235

d

= 2413

h

Setting of the monitoring of the direction of movement of the motor during normal operation

Selection list

(read only)

Information

0 Both directions enabled

(From SM301 V1.3)

1 Positive direction enabled

2 Negative direction enabled

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15341

SDI: Deceleration time

UNSIGNED_16

9234

d

= 2412

h

Safely monitored time from activation to switching on the monitoring SDIpos/SDIneg

Display area

(min. value | unit | max. value)

Information

0

ms

30000

(From SM301 V1.3)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15342

SDI: Tolerance threshold

UNSIGNED_32

9233

d

= 2411

h

Setting of the tolerance threshold by how many increments the motor may move towards the direction
inhibited through SDI

Display area

(min. value | unit | max. value)

Information

0

Incr.

327680

(From SM301 V1.3)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15343

SDI: Error response

UNSIGNED_8

9232

d

= 2410

h

Response to a violation of the permitted direction of movement of the motor

Selection list

(read only)

Information

0 STO

(From SM301 V1.3)

1 SS1

2 SS2

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15344

SDI: Maximum change in position

UNSIGNED_32

9231

d

= 240F

h

Maximum change in position in inhibited direction if SDI is active

Display area

(min. value | unit | max. value)

Information

0

Incr.

2147483647

Subcodes

Information

C15344/1

SDIpos: Maximum change in position

(from SM301 V1.3)

C15344/2

SDIneg: Maximum change in position

(from SM301 V1.3)

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

1.3.10.2

Activation

How to activate the "Safe direction" function:

ƒ

Permanent monitoring of the direction of movement during normal operation
(C15340).

ƒ

"OFF state" at a safe input, the function of which has been assigned by parameter
setting.

ƒ

In conjunction with safely limited speed SLSx (C15333).

ƒ

Via a safety bus data telegram with corresponding content.