Safety engineering, Appendix module internal codes – Lenze E94AYAE SM301 User Manual

Page 120

Advertising
background image

Safety engineering

Appendix
Module internal codes

1

l

120

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15060

Output image

BITFIELD_16

9515

d

= 252B

h

Output image of the safety module feedback, shown in channels.

Value is bit coded:

Information

Bit 0 SD-Out1 channel A

Safe output 1

Bit 1 SD-Out1 channel B

Bit 2 reserved

...

Bit 15 reserved

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15100

S bus: Configuration

UNSIGNED_8

9475

d

= 2503

h

Configuration of the safety bus

Selection list

(Lenze setting bold)

Information

0 No safety bus

1 PROFIsafe / PROFIBUS

2 PROFIsafe / PROFINET

(As of SM301 V1.1)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15101

Display − DIP switch position

UNSIGNED_16

9474

d

= 2502

h

Display of the DIP switch position

Display area

(min. value | unit | max. value)

Information

0

1023

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15111

Safety address

UNSIGNED_16

9464

d

= 24F8

h

Safety address parameterised in the safety module

Setting range

(min. value | unit | max. value)

Information

0

65534 Lenze: 0

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15112

Effective safety address

UNSIGNED_16

9463

d

= 24F7

h

Address used in safety module

Display area

(min. value | unit | max. value)

Information

1

65534

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

Advertising