Safe bus interfaces, Profisafe connection, Safety engineering – Lenze E94AYAE SM301 User Manual

Page 90

Advertising
background image

Safety engineering

Safe bus interfaces
PROFIsafe connection

1

l

90

EDS94AYAE EN 7.0

1.5

Safe bus interfaces

In the safety module, parameterised interfaces are provided for standardised safety bus
systems. With the selection of the bus system, the corresponding parameters are made
available.

Currently supported communication types:

ƒ

Operation without safety bus system

ƒ

Operation with PROFIsafe protocol

Codes

Parameter:

Name:

Data type:

Index:

C15100

S bus: Configuration

UNSIGNED_8

9475

d

= 2503

h

Configuration of the safety bus

Selection list

(Lenze setting bold)

Information

0 No safety bus

1 PROFIsafe / PROFIBUS

2 PROFIsafe / PROFINET

(As of SM301 V1.1)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

1.5.1

PROFIsafe connection

1.5.1.1

Conditions

The SM301 supports the transmission of safe information on the PROFIsafe protocol
according to the "PROFIsafe − Profile for Safety Technology" specification, version 1.30, of
the PROFIBUS Nutzerorganisation (PNO). The SM301 V1.1 also supports the PROFIsafe
protocol according to the "PROFIsafe − Profile for Safety Technology" specification, version
2.x. The standard device transmits the PROFIsafe information to the safety module for safe
evaluation.

PROFIsafe connection

Required

communication module

Setting

"S BUS: Configuration" (C15100)

PROFIBUS

E94AYCPM (PROFIBUS−DP)

as of software version V1.00

PROFIsafe / PROFIBUS

PROFINET

(as of SM301 V1.1)

E94AYCER (PROFINET)

as of software version V0.70

PROFIsafe / PROFINET

)

Note!

A safety bus system (PROFIsafe) can only be operated via the upper module
slot (MXI1) of the Servo Drive 9400.

)

Note!

The operation with PROFIsafe via PROFINET is only permissible according to
the "PROFIsafe − Profile for Safety Technology" specification, version 2.x.