Safe torque off, Safety engineering, Safety functions safe torque off – Lenze E94AYAE SM301 User Manual

Page 54

Advertising
background image

Safety engineering

Safety functions
Safe torque off

1

l

54

EDS94AYAE EN 7.0

1.3.3

Safe torque off

1.3.3.1

Description

Safe Torque Off/STO

This function corresponds to a "Stop 0" according to EN 60204.

When this function is used, the power supply of the motor is immediately (t1) safely
interrupted. The motor cannot create a torque and thus no dangerous movements of the
drive can occur. Additional measures, e.g. mechanical brakes are needed against
movements caused by external force.

t

t

n

0

0

1

2

t1

I

STO

t1

t

0

I

0

SM301DIA_STO

0 Input signal of the request of a safety function

I

ON state

O OFF state

1 Speed characteristic n of the motor

t

Time axis

tx Action instant

2 Feedback(s)

The restart behaviour can be set (C15300/1). Function sequence and error response have
no adjustable parameters.

Codes

Parameter:

Name:

Data type:

Index:

C15300

Restart behaviour

UNSIGNED_8

9275

d

= 243B

h

Behaviour for restart after functions have been cancelled

Selection list

(Lenze setting bold)

Information

0 Acknowledged restart

1 Automatic restart

Subcodes

Information

C15300/1

Restart - STO, SS1

C15300/2

Restart - SS2, SOS

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer