Safety functions
Integration into the application of the controller

1

l

52

EDS94AYAE EN 7.0

1.3.2.1

Control information

The safety module transfers information via requested or active safety functions with the
control word SMI_dwControl. The application in the standard device must evaluate the
control word and execute the corresponding action.

The following table shows the bit coding of the control word.

Control word − SMI_dwControl

Bit

Name

Meaning

1

SS1 active

Safe stop 1 requested

2

SS2 active

Safe stop 2 requested

3

SLS1 active

Safely limited speed 1 requested
When the braking time Nlim1 parameterised has elapsed, bit 8 of the
SMI_dnState status signal (SLS1 monitored) is set additionally.

4

SLS2 active

Safely limited speed 2 requested

(as of SM301 V1.1)

When the braking time Nlim2 parameterised has elapsed, bit 9 of the
SMI_dnState status signal (SLS2 monitored) is set additionally.

5

SLS3 active

Safely limited speed 3 requested

(as of SM301 V1.1)

When the braking time Nlim3 parameterised has elapsed, bit 10 of the
SMI_dnState status signal (SLS3 monitored) is set additionally.

6

SLS4 active

Safely limited speed 4 requested

(as of SM301 V1.1)

When the braking time Nlim4 parameterised has elapsed, bit 11 of the
SMI_dnState status signal (SLS4 monitored) is set additionally.

7

SDIpos is active

The safe positive direction of movement (SDIpos) function is active.

(As of SM301

V1.3)

After the parameterised SDI deceleration time has expired, bit 12 of the status
signal SMI_dnState (SdIpos monitored) is set in addition.

8

SDIneg is active

The safe negative direction of movement (SDIneg) function is active.

(As of

SM301 V1.3)

After the parameterised SDI deceleration time has expired, bit 13 of the status
signal SMI_dnState (SdIneg monitored) is set in addition.

9

ES active

Motion functions in special operation requested

10

SLI is active

Safely limited increment is active.

(As of SM301 V1.4)

11

OMS

Operation mode selector (OMS) function for special operation has been
requested.
(0 = normal operation)

16

SOS is active

Safe operational stop maintained

23

SSE active

Emergency stop active (Safe Stop Emergency)

29

OMS active

Special operation active (Operation Mode Selector)

(from SM301 V1.1)

1.3.2.2

Status information

The safety module transfers information via the status of safety functions with the
SMI_dnState status word.

The SMI_dnIoState status word contains information on the status of the safe inputs and
the safe output. The application in the standard device can evaluate and use the status
words for additional tasks.

The following tables show the bit coding of the status words:

Advertising