Safety engineering

Device modules

Safe output

1

l

39

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15052

SD-Out condition

BITFIELD_32

9523

d

= 2533

h

Bit coded selection of the conditions for switching the safe output.

Value is bit coded:

Information

Bit 0 SOS monitored

Safe operational stop is monitored.

Bit 1 SOS monitors neg. logic

Safe operational stop is not monitored.

Bit 2 SLS1 monitored

Safely limited speed 1 is monitored.

Bit 3 SLS1 monitored neg. logic

Safely limited speed 1 is not monitored.

Bit 4 SLS2 monitored

Safely limited speed 2 is monitored.

(from SM301 V1.1)

Bit 5 SLS2 monitors neg. logic

Safely limited speed 2 is not monitored.

(from SM301 V1.1)

Bit 6 SLS3 monitored

Safely limited speed 3 is monitored.

(from SM301 V1.1)

Bit 7 SLS3 monitors neg. logic

Safely limited speed 3 is not monitored.

(from SM301 V1.1)

Bit 8 SLS4 monitored

Safely limited speed 4 is monitored.

(from SM301 V1.1)

Bit 9 SLS4 monitors neg. logic

Safely limited speed 4 is not monitored.

(from SM301 V1.1)

Bit 10 SDIpos monitored

Safe positive direction is monitored.

(from SM301 V1.3)

Bit 11 SDIpos monitors neg. logic

Safe positive direction is not monitored.

(from SM301 V1.3)

Bit 12 SDIneg monitored

Safe negative direction is monitored.

(from SM301 V1.3)

Bit 13 SDIneg monitors neg. logic

Safe negative direction is not monitored.

(from SM301 V1.3)

Bit 14 SSE active

Emergency stop function

Bit 15 SSE active neg. logic

Bit 16 SD−In1 active

Safe inputs

Bit 17 SD−In1 active neg. logic

Bit 18 SD−In2 active

Bit 19 SD−In2 active neg. logic

Bit 20 SD−In2 active

Bit 21 SD−In2 active neg. logic

Bit 22 SD−In4 active

Bit 23 SD−In4 active neg. logic

Bit 24 Reserved

Bit 25 Reserved

Bit 26 OMS active

Special operation is active

(from SM301 V1.1)

Bit 27 OMS active neg. logic

Special operation is not active

(from SM301 V1.1)

Bit 28 Reserved

Bit 29 Reserved

Bit 30 Error active

Bit 31 Error active neg. logic

Subcodes

Information

C15052/1

SD-Out1 switching condition

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15055

SD−Out logic function

UNSIGNED_8

9520

d

= 2530

h

Selection of the logic operation for the switching conditions to be evaluated

Selection list

(Lenze setting bold)

Information

0 OR

1 AND

Subcodes

Information

C15055/1

SD−Out1 logic function

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer