Safety engineering, Device modules safe inputs – Lenze E94AYAE SM301 User Manual

Page 36

Advertising
background image

Safety engineering

Device modules
Safe inputs

1

l

36

EDS94AYAE EN 7.0

1.2.4.3

Connection of active sensors

The safe sensor inputs I1A ... I4B are suitable for active sensors.

PN−switched input signals are permissible.

The line monitoring must comply with the requirements of the category 3. Drive−based
safety does not provide for line monitoring.

These errors are detected:

ƒ

Non−equivalent input signals after the discrepancy time.

1.2.4.4

Example circuits

G x

I

IxB

IxA

SM...

S

SSP94SM352

Fig. 1−9

Example circuit − active sensor

G x

I

IxB

IxA

SM...

S

M

P

SSP94SM352

Fig. 1−10

Functional example of PN−switching sensor

S

Sensor

P

Positive path

M

Negative path