Safety engineering – Lenze E94AYAE SM301 User Manual

Page 18

Advertising
background image

Safety engineering

Device modules
SM301 safety module

1

l

18

EDS94AYAE EN 7.0

Motor−encoder combinations

Drive systems with Servo Drives 9400 and safety module SM301 provide speed−dependent
safety functions for safe speed monitoring and/or safe relative−position monitoring.
Observe permissible motor−encoder combinations during configuration.

ƒ

Possible speed−dependent safety functions with safety module SM301:

– Safe stop 1 (SS1)

– Safe operational stop (SOS)

– Safely limited speed (SLS)

– Safe maximum speed (SMS)

– Safe direction (SDI)

– Safe speed monitor (SSM)

– Safely limited increment (SLI)

ƒ

Permissible motor−encoder combinations for these functions:

Synchronous
servo motors

Encoder

Safe speed monitoring with SM301

Type

Product key

MCS 06 ... 19
MDXKS 56 / 71

Sin/cos absolute value, single−turn

AS1024−8V−K2

Single−encoder

concept

PL d / SIL 2

Sin/cos absolute value, multi−turn

AM1024−8V−K2

Resolver

RV03

PL e / SIL 3

Two−encoder concept Up to PL e / SIL 3

Asynchronous
servo motors

Encoder

Safe speed monitoring with SM301

Type

Product key

MCA 10 ... 26
MQA 20 ... 26

Sin/cos incremental

IG1024−5V−V3

Single−encoder

concept

PL e / SIL 3

Resolver

RV03

Two−encoder concept Up to PL e / SIL 3

Three−phase
asynchronous
motors

Encoder

Safe speed monitoring with SM301

Type

Product key

MDxMA063−xx ...
MDxMA225−xx

Sin/cos incremental

IG2048−5V−V3

Single−encoder

concept

PL e / SIL 3

MHxMA080−xx ...
MHxMA225−xx

IG2048−5V−V2

PL d / SIL 2

MFxMA063−xx ...
MFxMA132−xx

Two−encoder

concept

Up to PL e / SIL 3

A "two−encoder concept" includes e.g. a resolver as motor encoder and, at the same time,
an absolute value encoder (sin/cos), an incremental encoder (TTL), or digital encoder
(SSI/bus) as position encoder on the machine.

In the case of the "2−encoder concept", the achievable risk mitigation (PL/SIL) depends on
the suitability of the encoders used.

)

Note!

If feedback systems for safety functions are used, the manufacturer’s
documentation must be observed!

Advertising