Module error messages, Safety engineering, Appendix module error messages – Lenze E94AYAE SM301 User Manual

Page 133

Advertising
background image

Safety engineering

Appendix

Module error messages

1

l

133

EDS94AYAE EN 7.0

1.10.2

Module error messages

The Parameterisation & Configuration Software Manual provides information on
diagnostics & fault analysis and describes the structure of the operating system’s error
messages in the logbook.

Entries

Field

Description

Error type/response/
Note

Error number

Internal

1

0x01

Internal error, STO is active

Replace safety module.
Consultation with Lenze is
required.

2

0x02

Internal error, SS1 is active

3

0x03

Internal error, SS2 is active

Communication − standard device

16

0x10

Communication error − standard device
(communication between standard device and SM301 cancelled)

Warning/STO

17

0x11

Synchronisation error − standard device

No error status
Logbook entry/info

PROFIsafe

33

0x21

Safety address is invalid (0 or 0xFFFF)

34

0x22

PROFIsafe communication error

PROFIsafe passivated/−
No error status
No diagnostic telegram via
PROFIBUS

35

0x23

F_WD_Time exceeded
(PROFIsafe monitoring time activated)

36

0x24

PROFIsafe deactivated

37

0x25

PROFIsafe has quit Data Exchange

38

0x26

PROFIsafe invalid data

39

0x27

Error − F parameter
(Wrong parameter setting of the F PLC)

PROFIsafe parameter
setting/STO
No error status

40

0x28

Communication error in parameter phase

Inputs

49

0x31

Error − discrepancy or functional test SD−In1

Trouble/−
OFF state for the affected
input

50

0x32

Error − discrepancy or functional test SD−In2

51

0x33

Error − discrepancy or functional test SD−In3

52

0x34

Error − discrepancy or functional test SD−In4

53

0x35

Internal error AIS

54

0x36

Internal error AIE

55

0x37

Internal error − module switch

57

0x39

Deactivated SD−In1 = high
(Initialisation error, input in ON state)

Trouble/STO

58

0x3A

Deactivated SD−In2 = high

59

0x3B

Deactivated SD−In3 = high

60

0x3C

Deactivated SD−In4 = high