Safety engineering

Appendix
Module internal codes

1

l

116

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15032

SD-In free assignment

UNSIGNED_8

9543

d

= 2547

h

Assignment of a safety function to a safe input.

l

Only possible if the "free assignment" sensor function is set for the safe input in C15031.

Selection list

(Lenze setting printed in bold)

Information

0 STO

Safe torque off

1 SS1

Safe stop 1

2 SS2

Safe stop 2

3 SLS1

Safely limited speed 1

4 SLS2

Safely limited speed 2

(from SM301 V1.1)

5 SLS3

Safely limited speed 3

(from SM301 V1.1)

6 SLS4

Safely limited speed 4

(from SM301 V1.1)

7 SDIpos

Safe positive direction

(from SM301 V1.3)

8 SDIneg

Safe negative direction

(from SM301 V1.3)

9 No function

No (local) safety function assigned.

l

Functional test and monitoring of the discrepancy
time are active.

l

The input status is transferred to the control via the
safety bus (if parameterised).

Subcodes

Information

C15032/1

Free assignment SD-In1

C15032/2

Free assignment SD-In2

C15032/3

Free assignment SD-In3

C15032/4

Free assignment SD-In4

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15033

SD-In discrepancy time

UNSIGNED_16

9542

d

= 2546

h

Maximum time in which both channels of a safe input may have non−equivalent states without the safety
engineering causing an error response.

Setting range

(min. value | unit | max. value)

Information

0

MS

30000 Lenze: 10, increment: 2 ms

Subcodes

Information

C15033/1

SD-In1 discrepancy time

C15033/2

SD-In2 discrepancy time

C15033/3

SD-In3 discrepancy time

C15033/4

SD-In4 discrepancy time

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15034

SD-In input delay

UNSIGNED_8

9541

d

= 2545

h

Time between the recognition of the signal change and the effective evaluation of an input signal. As a result,
multiple and short signal changes due to contact bounce of the components are not taken into account.

Setting range

(min. value | unit | max. value)

Information

0

MS

100 Lenze: 0, increment: 2 ms

Subcodes

Information

C15034/1

Input delay SD-In1

C15034/2

Input delay SD-In2

C15034/3

Input delay SD-In3

C15034/4

Input delay SD-In4

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer