Safety engineering, Safe bus interfaces profisafe connection – Lenze E94AYAE SM301 User Manual

Page 95

Advertising
background image

Safety engineering

Safe bus interfaces

PROFIsafe connection

1

l

95

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15115

S-bus: Control data display

BITFIELD_32

9460

d

= 24F4

h

Display of safety bus control data after filtering via C15113

Value is bit coded:

Information

(From SM301 V1.2)

Bit 0 STO

Safe torque off

Bit 1 SS1

Safe stop 1

Bit 2 SS2

Safe stop 2

Bit 3 SLS1

Safely limited speed 1

Bit 4 SLS2

Safely limited speed 2

Bit 5 SLS3

Safely limited speed 3

Bit 6 SLS4

Safely limited speed 4

Bit 7 SDIpos

Safe positive direction

(From SM301 V1.3)

Bit 8 SDIneg

Safe negative direction

(From SM301 V1.3)

Bit 9 ES

Safe enable switch

Bit 10 Reserved

Bit 11 OMS

Safe operation mode selector

Bit 12 Reserved

...

Bit 15 Reserved

Bit 16 PS_AIS

Restart acknowledgement via safety bus

Bit 17 PS_AIE

Fault acknowledgement via safety bus

Bit 18 Reserved

...

Bit 22 Reserved

Bit 23 SSE

Emergency stop function

Bit 24 SD−Out1

Safe output

Bit 25 Reserved

...

Bit 31 Reserved

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer