Safety engineering, Device modules safe output, 2 example circuits – Lenze E94AYAE SM301 User Manual
Page 40
Advertising

Safety engineering
Device modules
Safe output
l
40
EDS94AYAE EN 7.0
Index:
Data type:
Name:
Parameter:
C15060
Output image
BITFIELD_16
9515
d
= 252B
h
Output image of the safety module feedback, shown in channels.
Value is bit coded:
Information
Bit 0 SD-Out1 channel A
Safe output 1
Bit 1 SD-Out1 channel B
Bit 2 reserved
...
Bit 15 reserved
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
1.2.5.2
Example circuits
GO
24O
GO
O1B
O1A
SSP94SM360
24O, GO
24−V voltage supply for the safe output
O1A, O1B, GO
Safe output SD−Out1, channel A and B with reference potential
24−V voltage supply − safe output (SELV/PELV) acc. to IEC 61131−2
Input of a higher−level unit (e.g. safety PLC)
Advertising