Safety engineering, Appendix module internal codes – Lenze E94AYAE SM301 User Manual

Page 128

Advertising
background image

Safety engineering

Appendix
Module internal codes

1

l

128

EDS94AYAE EN 7.0

Index:

Data type:

Name:

Parameter:

C15410

Response time of encoder monitoring

UNSIGNED_8

9165

d

= 23CD

h

Max. internal time after which encoder errors lead to a system response

Selection list

Information

0 12 ms

(As of SM301 V1.2)

(From SM301 V1.4: Resolver is sole encoder

W

50 or 100 ms)

10 50 ms

20 100 ms

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15411

Tolerance of speed comparison

UNSIGNED_16

9164

d

= 23CC

h

Tolerance of the speed comparison in the safety module

Display area

(min. value | unit | max. value)

Information

0

rpm

16000

(From SM301 V1.3)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15420

Number of increments − sin/cos encoder

UNSIGNED_16

9155

d

= 23C3

h

Number of increments of the sin/cos encoder used

Setting range

(min. value | unit | max. value)

Information

1

16384 Lenze: 1

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15430

Number of pole pairs of resolver

UNSIGNED_8

9145

d

= 23B9

h

Number of pole pairs of the used resolver

Setting range

(min. value | unit | max. value)

Information

1

10 Lenze: 1

(From SM301 V1.3)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15500

Position encoder system

UNSIGNED_8

9075

d

= 2373

h

Setting of the connected position encoder system

Selection list

(read only)

Information

0 No position encoder

(From SM301 V1.3)

1 Analog encoder (Sin−Cos/TTL)

2 Digital encoder (SSI/BUS)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15501

Position encoder − gearbox factor

UNSIGNED_16

9074

d

= 2372

h

Setting of the gearbox factor between motor and position encoder

Display area

(min. value | unit | max. value)

Information

20

%

50000 Lenze: 100

(From SM301 V1.3)

100

º i = 1.00

2543

º i = 25.43

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15502

Position encoder − mounting direction

UNSIGNED_8

9073

d

= 2371

h

Setting of the mounting direction of the position encoder regarding the motor encoder

Selection list

(read only)

Information

0 Like motor encoder

(From SM301 V1.3)

If the mounting directions of the motor (C02527/0)
and position encoder (C02529/0) in the standard
device are set in different directions of rotation, this
parameter must be set to "inverted to the motor
encoder".

1 Inverted to the motor encoder

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer