Safety engineering

Appendix
Module error messages

1

l

136

EDS94AYAE EN 7.0

Error type/response/
Note

Description

Field

Error type/response/
Note

Description

Error number

Test functions − inputs

144

0x90

Stuck at High SD−In1, channel A
(Short circuit (High)

Trouble/−
SD−In1: OFF state

145

0x91

Stuck at High SD−In1, channel B

146

0x92

Stuck at High SD−In2, channel A

Trouble/−
SD−In2: OFF state

147

0x93

Stuck at High SD−In2, channel B

148

0x94

Stuck at High SD−In3, channel A

Trouble/−
SD−In3: OFF state

149

0x95

Stuck at High SD−In3, channel B

150

0x96

Stuck at High SD−In4, channel A

Trouble/−
SD−In4: OFF state

151

0x97

Stuck at High SD−In4, channel B

154

0x9A

CLA/CLB short circuit
Short circuit between the CLA and CLB clock outputs

Trouble/−
SD−In: OFF state

Safe parameterisation

160

0xA0

New parameter set deleted
(by the safe parameter setting in the Engineer)

−/−
Logbook entry: Info

161

0xA1

New safe parameter set loaded
(by the safe parameter setting in the Engineer or the procedure
with the module switch)

162

0xA2

Memory module parameter set − access error
(Error while accessing the parameter set of the memory module.)

Trouble/STO
OFF state for all SD−In and
SD−Out

163

0xA3

Different parameter sets
(in the memory module and SM301)

164

0xA4

No safe parameter set in the safety module
(SM301 has no parameter set.)

165

0xA5

Defective parameter set
(SM301 parameter set is defective.)

166

0xA6

Parameter set in memory module − format error
(Format error in parameter set of memory module)

167

0xA7

Parameter set − plausibility error

168

0xA8

Parameter set − communication error
(Communication error when loading the parameter set)

169

0xA9

Module ID does not equal effective safety address
(Module ID in the parameter set does not equal the effective
safety address)

Warning/STO
OFF state for all SD−In and
SD−Out

Test functions − internal module

192

0xC0

Reference voltage error

Trouble/STO
OFF state for all SD−In and
SD−Out

193

0xC1

6 V voltage error

194

0xC2

5 V voltage error

195

0xC3

2.6 V voltage error

208 0xD0

Safe speed is invalid

Trouble/STO

209 0xD1

SSM: Encoder error

Trouble/STO

210 0xD2

SSM: Resolver error

Trouble/STO

211 0xD3

SSM: Standard device data error

Trouble/STO

212 0xD4

SSM: Speed comparison error

213 0xD5

SSM: Synchronisation error

214 0xD6

SSM: Wrong PDO version

Trouble/STO

Tab. 1−24

Description of the numerical entries