Safety engineering – Lenze E94AYAE SM301 User Manual

Page 23

Advertising
background image

Safety engineering

Device modules

SM301 safety module

1

l

23

EDS94AYAE EN 7.0

X82.3

Labelling

Description

GCL

GND clock output

GI2

GND SD−In2

I2B

Sensor input SD−In2, channel B

I2A

Sensor input SD−In2, channel A

GCL

GND clock output

GI1

GND SD−In1

I1B

Sensor input SD−In1, channel B

I1A

Sensor input SD−In1, channel A

AIS

Restart acknowledgement input ("Acknowledge In Stop", 1−channel,
bridged to X82.4/AIS)

X82.4

Labelling

Description

GCL

GND clock output

GI4

GND SD−In4

I4B

Sensor input SD−In4, channel B

I4A

Sensor input SD−In4, channel A

GCL

GND clock output

GI3

GND SD−In3

I3B

Sensor input SD−In3, channel B

I3A

Sensor input SD−In3, channel A

AIS

Restart acknowledgement input ("Acknowledge In Stop", 1−channel,
bridged to X82.3/AIS)

Cable cross−sections and tightening torques

Type

[mm

2

]

[Nm]

AWG

[lb−in]

Wire end ferrule,
insulated

0.25 ... 0.75

Spring terminal

24 ... 18

Spring terminal

Rigid

0.14 ... 1.5

26 ... 16

Stripping length or contact length: 9 mm

Insulated wire end ferrules according to DIN 46228, part 4, 0.5 mm

2

or 0.75 mm

2

− length

L1 = 10 mm can be used.

)

Note!

Provide for a sufficient strain relief, so that the terminals are not pulled from
the plug connectors, in particular when you use rigid cables.