Safety engineering, Safety functions safe stop 1 – Lenze E94AYAE SM301 User Manual
Page 57
Advertising
Safety engineering
Safety functions
Safe stop 1
l
57
EDS94AYAE EN 7.0
2
SS1
STO
0
0
I
I
t1
t2
t
S
t
t
t
n
0
1
t1
t
0
I
0
SM301DIA_SS1
0 Input signal of the request of a safety function
I
ON state
0
OFF state
1 Speed characteristic n of the motor
l
Optional: Monitoring of the brake ramp as of SM301 V1.4
t
Time axis
tx Action instant
t
S
Monitored stopping time
–– Normal operation
−−− Incorrect operation
2 Feedback(s)
SS1 mode (C15306) influences the switching time and contains the
"SS1:Deceleration STO after n=0" (C15307)
Advertising