Safety engineering, Device modules safe output, Codes – Lenze E94AYAE SM301 User Manual

Page 38

Advertising
background image

Safety engineering

Device modules
Safe output

1

l

38

EDS94AYAE EN 7.0

Codes

Parameter:

Name:

Data type:

Index:

C15051

SD-Out condition

BITFIELD_32

9524

d

= 2534

h

Bit coded selection of the conditions for switching the safe output.

Value is bit coded:

Information

Bit 0 STO active

Safe torque off

Bit 1 STO active neg. logic

Bit 2 SS1 active

Safe stop 1

Bit 3 SS1 active neg. logic

Bit 4 SS2 active

Safe stop 2

Bit 5 SS2 active neg. logic

Bit 6 SLS1 active

Safely limited speed 1

Bit 7 SLS1 active neg. logic

Bit 8 SLS2 active

Safely limited speed 2

(From SM301 V1.1)

Bit 9 SLS2 active neg. logic

Bit 10 SLS3 active

Safely limited speed 3

(From SM301 V1.1)

Bit 11 SLS3 active neg. logic

Bit 12 SLS4 active

Safely limited speed 4

(as of SM301 V1.1)

Bit 13 SLS4 active neg. logic

Bit 14 SDIpos is active

Safe direction, positive

(From SM301 V1.3)

Bit 15 SDIpos active neg. logic

Bit 16 SDIneg is active

Safe direction, negative

(From SM301 V1.3)

Bit 17 SDIneg active neg. logic

Bit 18 ES active

Safe enable switch

Bit 19 ES active neg. logic

Bit 20 SLI is active

Safely limited increment

(From SM301 V1.4)

Bit 21 SLI active neg. logic

Bit 22 OMS

Safe operation mode selector

Bit 23 OMS neg. logic

Bit 24 Reserved

...

Bit 31 Reserved

Subcodes

Information

C15051/1

SD-Out1 switching condition

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

Advertising