Safety engineering – Lenze E94AYAE SM301 User Manual

Page 34

Advertising
background image

Safety engineering

Device modules
Safe inputs

1

l

34

EDS94AYAE EN 7.0

SSP94SM355

Fig. 1−5

Status behaviour − contact function test

A

B

C

D



SSP94SM358_1

Fig. 1−6

Contact function test − error−free input signals

A

B

C

D

AIE

‚

ƒ

„



SSP94SM358_2

Fig. 1−7

Contact function test − faulty input signals

A, B

Safe input, channel A and channel B

C

Internal valuation of the safe input

D

Discrepancy monitoring

AIE

Fault acknowledgement



Discrepancy monitoring active

‚

Discrepancy monitoring − time−out

ƒ

Fault acknowledgement impermissible

„

Fault acknowledgement permissible

Advertising