Safety engineering – Lenze E94AYAE SM301 User Manual

Page 62

Advertising
background image

Safety engineering

Safety functions
Safe stop 2

1

l

62

EDS94AYAE EN 7.0

2

t

t

t

n

0

1

t1

t2

t

S

SS2

SOS

0

0

I

I



t1

t

0

I

0

SM301DIA_SS2

0 Input signal of the request of a safety function

I

ON state

0

OFF state

1 Speed characteristic n of the motor

l

Speed−monitored up to SM301 V1.2

l

Position−monitored as of SM301 V1.3

l

Optional: Monitoring of the brake ramp as of SM301 V1.4

t

Time axis

tx Action instant
t

S

Monitored stopping time

2 Feedback(s)

 SS2 mode (C15308) influences the switching time

I

Tip!

Adapt the deceleration time for quick stop (C00105) of the standard device to
the stopping time SS1, SS2 (C15305).
The drive must have reached standstill before the stopping time has elapsed.

Advertising