Safety engineering, Safety address, Codes – Lenze E94AYAE SM301 User Manual

Page 89

Advertising
background image

Safety engineering

Safety address

1

l

89

EDS94AYAE EN 7.0

Codes

Parameter:

Name:

Data type:

Index:

C15017

Stored module ID

UNSIGNED_16

9558

d

= 2556

h

Module ID stored in the safety module

Display area

(min. value | unit | max. value)

Information

0

65535

(As of SM301 V1.2)

Default setting (invalid ID): 0
Stored ID defective: 65535

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15101

Display − DIP switch position

UNSIGNED_16

9474

d

= 2502

h

Display of the DIP switch position

Display area

(min. value | unit | max. value)

Information

0

1023

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer

C15111

Safety address

UNSIGNED_16

9464

d

= 24F8

h

Safety address parameterised in the safety module

Setting range

(min. value | unit | max. value)

Information

0

65534 Lenze: 0

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15112

Effective safety address

UNSIGNED_16

9463

d

= 24F7

h

Address used in safety module

Display area

(min. value | unit | max. value)

Information

1

65534

þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer