background image

Safety engineering

Safety functions
Safely limited speed

1

l

72

EDS94AYAE EN 7.0

Codes

Parameter:

Name:

Data type:

Index:

C15330

SLS: Limited speed Nlim

UNSIGNED_16

9245

d

= 241D

h

Setting of the limited speed

Setting range

(min. value | unit | max. value)

Information

0

rpm

16000 Lenze: 0

Subcodes

Information

C15330/1

SLS1: Limited speed Nlim1

C15330/2

SLS2: Limited speed Nlim2

(As of SM301 V1.1)

C15330/3

SLS3: Limited speed Nlim3

(As of SM301 V1.1)

C15330/4

SLS4: Limited speed Nlim4

(As of SM301 V1.1)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15331

SLS: Braking time Nlim

UNSIGNED_16

9244

d

= 241C

h

Safely monitored time for braking the drive to the limited speed set in C15330.

Setting range

(min. value | unit | max. value)

Information

0

MS

30000 Lenze: 0, increment: 2 ms

Subcodes

Information

C15331/1

SLS1: Braking time Nlim1

C15331/2

SLS2: Braking time Nlim2

(as of SM301 V1.1)

C15331/3

SLS3: Braking time Nlim3

(as of SM301 V1.1)

C15331/4

SLS4: Braking time Nlim4

(as of SM301 V1.1)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer

C15332

SLS: Response (n>Nlim)

UNSIGNED_8

9243

d

= 241B

h

Response in the safety module to the exceeding of the limited speed

Selection list

(Lenze setting bold)

Information

0 STO

Safe torque off

1 SS1

Safe stop 1

2 SS2

Safe stop 2

Subcodes

Information

C15332/1

SLS1: Response (n>Nlim1)

C15332/2

SLS2: Response (n>Nlim2)

(as of SM301 V1.1)

C15332/3

SLS3: Response (n>Nlim3)

(as of SM301 V1.1)

C15332/4

SLS4: Response (n>Nlim4)

(as of SM301 V1.1)

þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer