Safety engineering

Device modules

Further inputs

1

l

41

EDS94AYAE EN 7.0

1.2.6

Further inputs

AIS input

The restart (when setting "acknowledged restart", (

50)), after a stop function has been

executed, requires an acknowledgement at AIS input:

ƒ

Positive signal pulse of 0.3 ... 10 s (terminal X82.3 or X82.4).
– Evaluation of the negative edge.

Other equivalent option:

ƒ

Signal via the PROFIsafe bit PS_AIS
(if communication via safety bus is preferred)
– Evaluation of the positive edge.

AIE input

Errors require an acknowledgement at AIE input:

ƒ

Positive signal pulse of 0.3 ... 10 s (terminal X82.2).
– Evaluation of the negative edge.

Other equivalent option:

ƒ

Signal via the PROFIsafe bit PS_AIE
(if communication via safety bus is preferred)
– Evaluation of the positive edge.