About This Publication

This manual explains how the Kinetix 6200 and Kinetix 6500 drives can be used
in Safety Integrity Level (SIL) CL3, Performance Level [PLe], or Category
(CAT) 4 applications. It describes the safety requirements, including PFD and
PFH values and application verification information, and provides information
on configuring and troubleshooting the Kinetix 6200 and Kinetix 6500 drives
with safe speed monitoring.

Audience

Use this manual if you are responsible for designing, configuring, or
troubleshooting safety applications that use the Kinetix 6200 and Kinetix 6500
drives with safe speed monitoring.

You must have a basic understanding of electrical circuitry and familiarity with
Kinetix 6200 and Kinetix 6500 drives. You must also be trained and experienced
in the creation, operation, and maintenance of safety systems.

Conventions

In this manual, configuration parameters are in brackets. For example,
[Overspeed Response Time].

Terminology

This table defines common safety terms used in this manual.

Abbreviation

Full Term

Definition

1oo2

One out of Two

Refers to the behavioral design of a dual-channel safety system.

CAT

Category

EN

European Norm

European Standards (EN specifications) developed by the European Committee for Standardization
for the European Union.

ESPE

Electro-sensitive Protective Equipment

An assembly of devices and/or components working together for protective tripping or presence-
sensing purposes and comprising as a minimum:
Sensing devices
Controlling/monitoring devices
Output signal-switching devices (OSSD)

IEC

International Electrotechnical Commission

Non-profit, non-governmental international standards organization that prepares and publishes
international standards for all electrical, electronic, and related technologies, collectively known as
electrotechnology.

IGBT

Insulated Gate Bi-polar Transistors

Typical power switch used to control main current.

ISO

International Organization for Standardization

Voluntary organization whose members are recognized authorities on standards, each one
representing a different country.

OSSD

Output Signal Switching Device

The component of the electro-sensitive protective equipment (ESPE) connected to the control system
of a machine responds by going to the OFF-state when the sensing device is actuated during normal
operation.

PFD

Probability of Failure on Demand

The average probability of a system to fail to perform its design function on demand.

PFH

Probability of Failure per Hour

The probability of a system to have a dangerous failure occur per hour.

PL

Performance Level

EN ISO 13849-1 safety rating

S1

2094-SE02F-M00-S1 and 2094-EN02D-M01-S1

Catalog numbers for Kinetix 6200 and Kinetix 6500 drives with Safe Speed Monitoring functionality.

SFF

Safe Failure Fraction

The sum of safe failures plus the sum of dangerous detected failures divided by the sum of all failures.

SIL

Safety Integrity Level

A measure of a products ability to lower the risk that a dangerous failure could occur.

Advertising