Parameter Data

Appendix B

Safe Limited Speed
Change Safe Limited
Speed Configuration
(continued)

Safe Limited Speed
Hysteresis

Provides hysteresis for SLS_Out output when Safe
Limited Speed monitoring is active.

Default:

0

Range:

0% when [Operation Mode] =
SafeStop
SafeStop-DoorMonitor
SafeStop-SafeLimitedSpeed
SafeStop-SafeLimitedSpeed-DoorMonitor
SafeStop-SafeLimitedSpeed-EnableSwitch
SafeStop-SafeLimitedSpeed-DoorMonitor-EnableSwitch

10

100% when [Operation Mode] =

SafeStop-SafeLimitedSpeedStatusOnly

Safe Max Speed
Change Safe
Maximum Speed
Configuration

Safe Maximum Speed
Configuration

Enable Maximum Speed Monitoring.

Default:

Maximum Speed Monitoring Not Enabled

Options:

Maximum Speed Monitoring Not Enabled
Maximum Speed Monitoring Enabled

Safe Maximum Speed
Limit

Defines the maximum speed limit that is tolerated if
Safe Maximum Speed (SMS) monitoring is enabled.

Default:

0

Range:

0

65,535 rpm or mm/s

ratio based on revolutions or millimeters configuration
defined by the [Primary Feedback Units] parameter

Safe Maximum Speed
Monitoring Stop
Behavior

Defines the Stop Category that is initiated in the event
of a SMS Speed fault.

Default:

Use Safe Torque-Off with Check for Standstill

Options:

Use Safe Torque-Off with Check for Standstill
Use Configured Stop Type

Safe Max Accel
Change Safe
Maximum
Acceleration
Configuration

Safe Maximum
Acceleration
Configuration

Enable Maximum Acceleration Monitoring.

Default:

Maximum Acceleration Monitoring Not Enabled

Options:

Maximum Acceleration Monitoring Not Enabled
Maximum Acceleration Monitoring Enabled

Safe Maximum
Acceleration Limit

Defines the Safe Maximum Acceleration (SMA) limit,
relative to encoder 1, of the system is being monitored.

Default:

0

Range:

0

65,535 rpm or mm/s

ratio based on revolutions or millimeters configuration
defined by the [Primary Feedback Units] parameter

Safe Maximum
Acceleration
Monitoring Stop
Behavior

Defines the Stop Category that is initiated in the event
of an SMA Acceleration fault.

Default:

Use Safe Torque-Off with Check for Standstill

Options:

Use Safe Torque-Off with Check for Standstill
Use Configured Stop Type

Safe Direction
Change Safe
Direction Monitoring
Configuration

Safe Direction
Monitoring
Configuration

Enable Safe Direction Monitoring.

Default:

Safe Direction Monitoring Not Enabled

Options:

Safe Direction Monitoring Not Enabled
Safe Direction Monitoring Enabled

Monitor Type

Defines the monitor type if Safe Direction Monitoring is
enabled.

Options:

Always
During Safe Limited Speed

Safe Direction

Defines the allowable direction if Safe Direction
Monitoring is enabled.

Default:

Positive

Options:

Positive
Negative

Jitter Tolerance

The position limit in encoder units tolerated in the
wrong direction when Safe Direction Monitoring is
active.

Default:

10

Range:

0

65,535 deg or mm

ratio based on revolutions or millimeters configuration
defined by the [Primary Feedback Units] parameter

(1) Secondary feedback parameter settings are not required when the [Feedback Mode] parameter setting is single encoder.

Table 41 - Configurable Parameters and Settings (continued)

Tab

Parameter Name

Description

Values
(Safety Configuration Tool)