Chapter 5

General Device and Feedback Monitoring Configuration

General Parameter List

Set these parameters to configure general operation of the drive.

Table 16 - General Parameters

Tab

Parameter Name

Description

Values
(Safety Configuration Tool)

Safety
Change System
Configuration

System Configuration

Defines whether the drive is a single unit or if it occupies
a first, middle, or last position in a multi-axis cascaded
system.

Default:

Single Unit

Options:

Single Unit
Cascaded First Unit
Cascaded Middle Unit
Cascaded Last Unit

Operation Mode

Defines the primary operating mode of the speed
monitoring safety functions.

Default:

SafeStop

Options:

Disabled
SafeStop
SafeStop-DoorMonitor
SafeStop-SafeLimitedSpeed
SafeStop-SafeLimitedSpeed-DoorMonitor
SafeStop-SafeLimitedSpeed-EnableSwitch
SafeStop-SafeLimitedSpeed-DoorMonitor-EnableSwitch
SafeStop-SafeLimitedSpeedStatusOnly

Reset Type

Defines the type of reset used by the drive.

Default:

Manual Monitored

Options:

Automatic
Manual
Manual Monitored

Overspeed Response
Time

Configuration for the feedback interface sampling rate.

Default:

42 ms

Options:

42 ms
48 ms
60 ms
84 ms
132 ms
228 ms
420 ms