Hardware features, Figure 1 - 44-pin low-profile connector kit – Rockwell Automation 2094-EN02D-M01-S1 Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety Reference Manual User Manual

Page 24

Advertising
background image

24

Rockwell Automation Publication 2094-RM001C-EN-P - May 2013

Chapter 2

About the Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Features

Hardware Features

The drive features five dual-channel inputs, two sets of sourcing safety outputs,
and one bipolar safety output. You can configure dual-channel inputs to accept a
following-contact configuration with two normally closed contacts, or one
normally closed and one normally open contact. They can also be configured for
single channel operation.

These inputs also support output signal switching devices (OSSD). Each output
has integral pulse-test checking circuitry.

The 2090-K6CK-D44M (44-pin) low-profile connector kit is designed
specifically for use with the Kinetix 6200 and Kinetix 6500 modular drives.
Safety connections are made by using this connector kit.

Figure 1 - 44-pin Low-profile Connector Kit

Refer to

Wiring the Safety Connections

on

page 26

for the connector pinouts.

IMPORTANT

Single-channel operation does not meet SIL CL3, PLe, Cat 4 safety integrity.

28 27 26 25 24 23 22 21 20 19 18 17 15 14 0

AUX FEEDBACK

0 11 10 9 8 7 6 5 4 3 2 1

0 39 41 40 39 42 40 39 43 40 39 44 40

INPUTS

0 38 37 36 35 34 33 32 31 30 29

28 27 28 27 28 27 28 27

S1 ONL

Y

S1 ONL

Y

S0&S1 W/S0 DISABLED

Kinetix 6200 and Kinetix 6500

IAM/AM Power Module

(IAM power module is shown)

Kinetix 6200 and Kinetix 6500 Control Module
(2094-SE02F-M00-S1 is shown)

2090-K6CK-D44M

Low-profile Connector Kit

Auxiliary Feedback, I/O, and Safety
Terminal Blocks

Advertising