Rockwell Automation 2094-EN02D-M01-S1 Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety Reference Manual User Manual

Page 44

Advertising
background image

44

Rockwell Automation Publication 2094-RM001C-EN-P - May 2013

Chapter 5

General Device and Feedback Monitoring Configuration

Table 7 - Encoder Resolution 1000 lines/rev

Table 8 - Encoder Resolution 1024 lines/rev

Table 9 - Encoder Resolution 3000 lines/rev

Overspeed Response Time
Setting

Speed (RPM)

1

10

100

1000

10,000

12,000

42

2.503

2.533

2.833

5.833

35.833

42.500

48

1.252

1.267

1.417

2.917

17.917

21.250

60

0.626

0.633

0.708

1.458

8.958

10.625

84

0.313

0.317

0.354

0.729

4.479

5.313

132

0.156

0.158

0.177

0.365

2.240

2.656

228

0.078

0.079

0.089

0.182

1.120

1.328

420

0.039

0.040

0.044

0.091

0.560

0.664

Overspeed Response Time
Setting

Speed (RPM)

1

10

100

1000

10,000

11,718.75

42

2.445

2.475

2.775

5.775

35.775

41.504

48

1.222

1.237

1.387

2.887

17.887

20.752

60

0.611

0.619

0.694

1.444

8.944

10.376

84

0.306

0.309

0.347

0.722

4.472

5.188

132

0.153

0.155

0.173

0.361

2.236

2.594

228

0.076

0.077

0.087

0.180

1.118

1.297

420

0.038

0.039

0.043

0.090

0.559

0.648

Overspeed Response Time
Setting

Speed (RPM)

1

10

100

1000

4000

42

0.837

0.867

1.167

4.167

14.167

48

0.418

0.433

0.583

2.083

7.083

60

0.209

0.217

0.292

1.042

3.542

84

0.105

0.108

0.146

0.521

1.771

132

0.052

0.054

0.073

0.260

0.885

228

0.026

0.027

0.036

0.130

0.443

420

0.013

0.014

0.018

0.065

0.221

Advertising